UPS ULi 3KL–6KL · 3–6 kVA

Lithium UPS

48 V lithium rack UPS with 0 ms transfer and a 60 A charger.

  • 3–6 kVA
  • 48 V lithium
  • 0 ms transfer

Rated capacity

3,000 / 5,000 / 6,000 VA

Real power

3,000 / 5,000 / 5,100 W

Battery bus

40–64 VDC

ULi lithium rack UPS

Rated range

3–6 kVA

Rated capacity
3,000 / 5,000 / 6,000 VA
Real power
3,000 / 5,000 / 5,100 W
Battery bus
40–64 VDC
Transfer
0 ms mains → battery
Efficiency
93% mains / 98% ECO
Charger
60 A maximum
TL;DR

A lithium UPS from 3 to 6 kVA (ULi 3KL–6KL) that puts LiFePO4 cells in roughly the footprint of a VRLA unit. Longer cycle life, faster recharge and less weight for the same runtime.

Overview

What this platform is built to do.

The ULi series is a 3–6 kVA online UPS designed around a 48 V lithium battery. It uses a 2U rack chassis, a built-in 60 A charger, and a 0 ms transfer to battery. The output power factor is 1.0, so a 6 kVA model delivers 6 kW, not 5.4 kW.

The input accepts 110–280 VAC at 50% load and 176–280 VAC at full load, with a power factor above 0.98 and THDi below 8%. The output is a pure sine wave with ±1% regulation and THD below 3% on a linear load. Up to nine units can be paralleled for capacity or redundancy.

The ULi is a rack platform for server rooms, edge cabinets, and telecom sites where lithium is preferred for cycle life and footprint. It can run without a battery connected, which is useful for commissioning and for loads that only need power conditioning.

Lithium-native

48 V lithium platform with a 60 A charger and BMS integration.

0 ms transfer

Online double conversion with a pure sine wave output.

Parallel-ready

Up to nine units for capacity or redundancy.

Compact 2U

Rack chassis with RS232/USB monitoring.

ULi lithium rack UPS
ULi lithium rack UPS
48 V lithium rack modules
48 V lithium rack modules
Rack UPS in a tower orientation
Rack UPS in a tower orientation
Models & specifications

ULi 3KL–6KL · 3–6 kVA

Selected models and nominal values. The quotation confirms the exact configuration, battery, and documentation for the project.

Request a model sheet

ULi lithium UPS models

ModelCapacityReal powerBattery busDimensionsWeight
ULi 3KL-48V CN3,000 VA3,000 W40–64 VDC420 × 438 × 132.5 mm15 kg
ULi 5KL-48V CN5,000 VA5,000 W40–64 VDC420 × 438 × 132.5 mm15 kg
ULi 6KL-48V CN6,000 VA5,100 W40–64 VDC420 × 438 × 132.5 mm15 kg

Input

Voltage
220/230/240 VAC
Voltage range
110–280 VAC at 50% load; 176–280 VAC at 100%
Frequency
46–54 Hz or 56–64 Hz
Input PF
≥ 0.98 at rated voltage, 100% load
THDi
≤ 8%

Output

Voltage
220/230/240 VAC
Regulation
±1% in battery mode
THD
≤ 3% linear; ≤ 5% non-linear
Transfer
0 ms mains → battery; 4 ms inverter → bypass
Power factor
1.0
Efficiency
93% mains / 98% ECO / 93% battery

Battery and mechanical

Battery voltage
40–64 VDC
Float voltage
54 VDC
Overcharge protection
64 VDC
Max charge current
60 A
Dimensions
420 × 438 × 132.5 mm
Weight
15 kg
Communication
RS232 and USB

Key specifications

ParameterValue
Rated capacity3,000 / 5,000 / 6,000 VA
Real power3,000 / 5,000 / 5,100 W
Battery bus40–64 VDC
Transfer0 ms mains → battery
Efficiency93% mains / 98% ECO
Charger60 A maximum

Selection notes for this family

QuestionWhat to checkWhy
Load profileRunning kW and largest step for 3–6 kVAAvoid overload and oversizing
RuntimeBattery bank and charger for the target minutesActual autonomy
EnvironmentTemperature, altitude, dust and ventilationLife and derating
InterfaceMonitoring, bypass, parallel requirementIntegration with the room
DocumentationConformity route and model test reportCustoms and tender
Applications

Where this family fits.

These are the load types the platform is specified for. If your load is outside this list, send the load profile before selecting the model.

  • Server rooms
  • Edge cabinets
  • Telecom sites
  • Branch IT
  • Rack deployments
FAQ

Lithium UPS: project questions.

Project-specific answers. If your question is not here, send the load list and the site conditions.

Talk to an engineer

Can the ULi run without a battery?

Yes. The UPS can operate without a battery connected, which is useful for commissioning and for loads that only need power conditioning. It will not provide backup in that mode.

How many units can be paralleled?

Up to nine units. The parallel configuration, shared battery arrangement, and bypass must be confirmed for the project.

Is it only for lithium batteries?

The ULi is designed around a 48 V lithium platform with a 60 A charger. Do not connect a lead-acid string without confirming the charger profile and the BMS compatibility.

What runtime can I get?

The runtime depends on the 48 V lithium bank capacity and the load. A 100 Ah module stores about 5.12 kWh; at 3 kW load and 93% efficiency, the ideal runtime is about 1.5 hours before derating.

Does it support remote monitoring?

Yes, RS232 and USB are standard. SNMP or dry contacts can be added through the monitoring option.

Next step

Send the load list. We will return the configuration.

Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.

  • Capacity and topology recommendation
  • Battery bank and runtime estimate
  • Model sheet and commercial offer