Skip to content
UPS NX Series · 10–600 kVA

NX Modular UPS

X+N redundancy, hot-swap modules, and a 600 kVA parallel ceiling.

  • 10–600 kVA
  • X+N redundancy
  • Hot-swap

Frame capacity

10–300 kVA

Parallel capacity

Up to 600 kVA

Redundancy

X+N

NX modular UPS cabinet

Rated range

10–600 kVA

Frame capacity
10–300 kVA
Parallel capacity
Up to 600 kVA
Redundancy
X+N
Efficiency
> 95%
Input THDi
< 3%
Battery bus
±240 VDC (32–40 blocks)
TL;DR

The NX modular UPS from 10 to 600 kVA uses X+N hot-swap modules, so redundancy is bought once and expanded module by module. It suits projects that need concurrent maintainability without a second parallel frame.

Overview

What this platform is built to do.

The NX series is a modular UPS for data centers and critical rooms that need to add capacity in steps. A single frame can reach 300 kVA; frames can be paralleled to 600 kVA. Power modules are hot-swappable, and the X+N configuration keeps the load online when a module is removed or fails.

The input stage uses IGBT rectification with a power factor above 0.99 and THDi below 3%. The output is regulated to ±1% with a 3:1 crest factor and THDV below 1% on a linear load. The battery bus is ±240 VDC with a configurable 32–40 block string, and the charger is sized at 20% of the system power.

NX is the right choice when the IT load will grow in phases, when N+1 must be maintained without a separate parallel system, or when the room needs a compact footprint. For a fixed small load, a monolithic high-frequency UPS may be more economical.

X+N redundancy

Keep the load online with one or more spare modules.

Hot-swap growth

Add or replace a module without transferring the load.

Parallel frames

Two frames reach 600 kVA for large rooms.

Efficient input

>0.99 input PF and <3% THDi reduce generator and cable burden.

NX modular UPS cabinet
NX modular UPS cabinet
Modular UPS frame range
Modular UPS frame range
Modular UPS in a data center
Modular UPS in a data center
Models & specifications

NX Series · 10–600 kVA

Selected models and nominal values. The quotation confirms the exact configuration, battery, and documentation for the project.

Request a model sheet

NX modular frame configurations

ConfigurationFrame capacityParallel ceilingModule optionsTypical use
Single frame10–300 kVA600 kVA with two frames10–50 kVA modulesServer room / small DC
X+N frame10–300 kVA600 kVA10–50 kVA modulesN+1 data center
Parallel frames2 × 300 kVA600 kVA10–50 kVA modulesLarge data center
Micro-module integrated30–600 kVA600 kVA10–50 kVA modulesPrefabricated room

Input

Voltage
380/400/415 VAC, 3-phase + N
Frequency
50/60 Hz, 40–70 Hz
Input PF
> 0.99
THDi
< 3%
Voltage range
−40% to +25%, with linear derating

Output

Voltage
380/400/415 VAC
Accuracy
±1% balanced; ±1.5% unbalanced
THDV
< 1% linear; < 3% non-linear
Crest factor
3:1
Overload
135% for 6 min; 135–150% for 1 min; >150% for 100 ms

Battery and monitoring

Battery bus
±240 VDC (32–40 blocks, settable)
Charge power
20% of system power
Charge voltage accuracy
±1%
Monitoring
SNMP, dry contacts, RS-485/RS-232

Key specifications

ParameterValue
Frame capacity10–300 kVA
Parallel capacityUp to 600 kVA
RedundancyX+N
Efficiency> 95%
Input THDi< 3%
Battery bus±240 VDC (32–40 blocks)

Selection notes for this family

QuestionWhat to checkWhy
Load profileRunning kW and largest step for 10–600 kVAAvoid overload and oversizing
RuntimeBattery bank and charger for the target minutesActual autonomy
EnvironmentTemperature, altitude, dust and ventilationLife and derating
InterfaceMonitoring, bypass, parallel requirementIntegration with the room
DocumentationConformity route and model test reportCustoms and tender
Applications

Where this family fits.

These are the load types the platform is specified for. If your load is outside this list, send the load profile before selecting the model.

  • Data centers
  • Server rooms
  • Micro-module rooms
  • Telecom core sites
  • Critical commercial facilities
FAQ

NX modular: project questions.

Project-specific answers. If your question is not here, send the load list and the site conditions.

Talk to an engineer

How many modules do I need for X+N?

Add N spare modules to the number required by the load. For a 120 kVA load with 30 kVA modules, four modules carry the load and one or more provide redundancy, depending on the target.

Can I parallel two NX frames?

Yes, two frames can be paralleled to 600 kVA. Confirm the parallel control, shared battery arrangement, and bypass design with the factory.

Does the frame include the battery?

The battery is external. The frame specifies a ±240 VDC bus with 32–40 blocks; the battery cabinet and runtime are project-specific.

Is the NX suitable for a small server room?

It can be, but a 10–20 kVA monolithic online UPS may be more economical for a fixed small load. NX is most valuable when growth and module-level redundancy matter.

What monitoring does it support?

SNMP, dry contacts, and RS-485/RS-232. The exact card set depends on the frame and the monitoring platform.

Next step

Send the load list. We will return the configuration.

Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.

  • Capacity and topology recommendation
  • Battery bank and runtime estimate
  • Model sheet and commercial offer

Request a configuration and quotation

Send the load list, backup time, and site conditions. We will return a capacity recommendation, battery configuration, and commercial offer.

By submitting this form you agree to our privacy policy. Privacy policy