Micro-Module Data Center
Prefabricated power, cooling, racks, and monitoring in one footprint.
- 2–10 racks
- 20–600 kVA
- Prefabricated
Rack count
2–10 racks
UPS
20–600 kVA modular
Cooling
3.5–60 kW row/room
Rated range
20–600 kVA
- Rack count
- 2–10 racks
- UPS
- 20–600 kVA modular
- Cooling
- 3.5–60 kW row/room
- PDU
- Rack PDU + distribution
- Monitoring
- Temperature, smoke, water, access, video
- Fire
- Gas suppression interface
A micro-module data centre from 20 to 600 kVA that integrates racks, precision cooling, UPS and monitoring as one room-scale system. It is delivered as a configured module rather than assembled from four separate trades on site.
What this platform is built to do.
A micro-module data center integrates the racks, the modular UPS, the row cooling, the PDU, the access control, and the environmental monitoring into a prefabricated footprint. It is used when the IT room must be deployed quickly, expanded in phases, or built in a space that is not a conventional data center.
The range includes pool-level and row-level configurations. The pool-level system uses a modular UPS from 30 to 600 kVA, row cooling from 12.5 to 60 kW, and a closed cold aisle. The row-level system uses 20–150 kVA modular UPS, 3.5–12.5 kW cooling, and 2–10 racks.
The micro-module is a project, not a box: the room, the power, the cooling, the fire detection, the access control, and the monitoring must be coordinated. Share the IT load, the rack count, the redundancy target, and the room dimensions for a layout.
Fast deployment
Prefabricated power, cooling, and racks reduce site work.
Phased growth
Add racks and UPS modules as the IT load grows.
Closed aisle
Cold/hot aisle containment improves cooling efficiency.
Integrated monitoring
Temperature, smoke, water, access, and video on one platform.
Pool-level / row-level · 20–600 kVA
Selected models and nominal values. The quotation confirms the exact configuration, battery, and documentation for the project.
Request a model sheetMicro-module configurations
| Configuration | Racks | UPS | Cooling | Typical use |
|---|---|---|---|---|
| Pool-level | Up to 10 | 30–600 kVA modular | 12.5–60 kW row | Small / medium DC |
| Row-level | 2–10 | 20–150 kVA modular | 3.5–12.5 kW | Edge / branch DC |
| Rack UPS | 2–8 | 5–20 kVA rack | 3.5–12.5 kW | Small IT room |
| Expansion | Add racks | Add modules | Add cooling | Phased build |
Configuration
- Pool-level racks
- Up to 10 racks
- Pool-level UPS
- 30–600 kVA modular
- Pool-level cooling
- 12.5–60 kW row cooling
- Row-level racks
- 2–10 racks
- Row-level UPS
- 20–150 kVA modular or 5–20 kVA rack UPS
- Row-level cooling
- 3.5–12.5 kW
Infrastructure
- PDU
- Rack PDU, 2 per rack
- Monitoring
- Temperature, humidity, smoke, water, door, video
- Fire
- Gas suppression interface and alarm
- Access
- Door access control per aisle
Key specifications
| Parameter | Value |
|---|---|
| Rack count | 2–10 racks |
| UPS | 20–600 kVA modular |
| Cooling | 3.5–60 kW row/room |
| PDU | Rack PDU + distribution |
| Monitoring | Temperature, smoke, water, access, video |
| Fire | Gas suppression interface |
Selection notes for this family
| Question | What to check | Why |
|---|---|---|
| Load profile | Running kW and largest step for 20–600 kVA | Avoid overload and oversizing |
| Runtime | Battery bank and charger for the target minutes | Actual autonomy |
| Environment | Temperature, altitude, dust and ventilation | Life and derating |
| Interface | Monitoring, bypass, parallel requirement | Integration with the room |
| Documentation | Conformity route and model test report | Customs and tender |
Where this family fits.
These are the load types the platform is specified for. If your load is outside this list, send the load profile before selecting the model.
- Edge data centers
- Branch IT rooms
- Telecom core
- Industrial IT
- Temporary / containerized rooms
Micro-module DC: project questions.
Project-specific answers. If your question is not here, send the load list and the site conditions.
Talk to an engineer What is a micro-module data center?
It is a prefabricated IT room that integrates racks, UPS, cooling, power distribution, access control, and monitoring. It is faster to deploy than a conventional data center build.
How many racks can it hold?
The pool-level system supports up to 10 racks; the row-level system supports 2–10 racks. The exact layout depends on the room and the cooling path.
Can it be expanded?
Yes. The modular UPS and the rack/cooling design allow phased expansion. Plan the power and cooling headroom at the initial build.
Does it include fire suppression?
The system provides the fire detection and the interface for gas suppression. The suppression cylinders and the approval are project-specific.
How is it shipped?
The modules are shipped as prefabricated sections or as a kit, depending on the size and the destination. The packing and the site assembly plan are confirmed in the project scope.
Send the load list. We will return the configuration.
Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.
- Capacity and topology recommendation
- Battery bank and runtime estimate
- Model sheet and commercial offer
Request a configuration and quotation
Send the load list, backup time, and site conditions. We will return a capacity recommendation, battery configuration, and commercial offer.