Battery 2 V / 12 V / 48 V · 4–2000 Ah

Specialty Battery Systems

Long-duration lead-acid and lithium blocks for large backup systems.

  • 4–2000 Ah
  • 2 V / 12 V / 48 V
  • VRLA & lithium

2 V cells

200–2000 Ah

12 V blocks

4–200 Ah

48 V lithium

50 / 100 Ah

Specialty battery block detail

Rated range

4–2000 Ah

2 V cells
200–2000 Ah
12 V blocks
4–200 Ah
48 V lithium
50 / 100 Ah
Chemistry
VRLA / LiFePO4
Installation
Rack, cabinet, or battery room
Applications
UPS, telecom, substation, solar
TL;DR

Specialty battery systems from 4 Ah to 2000 Ah in 2 V, 12 V and 48 V formats for switchgear, telecom and substation DC supplies. These are the strings that close breakers and hold protection relays, so cycle life and DC resistance matter more than energy density.

Overview

What this platform is built to do.

The specialty battery range covers the blocks that do not fit the standard 12 V 24–250 Ah UPS family: 2 V cells from 200 to 2000 Ah, 12 V blocks from 4 to 200 Ah, and 48 V lithium modules for rack and cabinet installations.

The 2 V cells are used in large UPS, telecom, and substation banks where the string voltage is built from high-capacity cells and the runtime is measured in hours. The 12 V blocks cover small UPS and security systems. The 48 V lithium modules are used in rack cabinets and hybrid systems.

Selection depends on the string voltage, the runtime, the charger, and the room. The 2 V cells need a battery rack and a trained installer; the 48 V lithium modules need a compatible BMS and charger. Share the UPS model and the runtime target for a configuration.

Large 2 V cells

High-capacity cells for long runtime and large strings.

12 V range

Small blocks for UPS, security, and solar systems.

48 V lithium

Rack modules with BMS for compact installations.

Project support

String layout, rack, and charger coordination.

Battery block detail
Battery block detail
12 V VRLA blocks
12 V VRLA blocks
48 V lithium rack modules
48 V lithium rack modules
Models & specifications

2 V / 12 V / 48 V · 4–2000 Ah

Selected models and nominal values. The quotation confirms the exact configuration, battery, and documentation for the project.

Request a model sheet

Specialty battery models

ModelVoltageCapacityTypeTypical use
AD12-10012 V100 AhVRLAUPS / solar
AD12-20012 V200 AhVRLATelecom / UPS
AJ2-5002 V530 AhVRLALarge UPS string
AJ2-10002 V1060 AhVRLASubstation / plant
AJ2-20002 V2120 AhVRLALong-duration bank
48V50AH48 V50 AhLiFePO4Rack / hybrid
48V100AH48 V100 AhLiFePO4Rack / hybrid

Lead-acid

2 V cells
AJ2-200 to AJ2-2000, 212–2120 Ah at 20 HR
12 V blocks
AD12-4 to AD12-200, 4–200 Ah at 20 HR
Type
VRLA, maintenance-free
Terminal
Model-dependent; bolt or front terminal

Lithium

48 V modules
48 V 50 Ah / 100 Ah
Chemistry
LiFePO4
BMS
Integrated, with communication
Application
Rack, cabinet, hybrid storage

Key specifications

ParameterValue
2 V cells200–2000 Ah
12 V blocks4–200 Ah
48 V lithium50 / 100 Ah
ChemistryVRLA / LiFePO4
InstallationRack, cabinet, or battery room
ApplicationsUPS, telecom, substation, solar

Selection notes for this family

QuestionWhat to checkWhy
Load profileRunning kW and largest step for 4–2000 AhAvoid overload and oversizing
RuntimeBattery bank and charger for the target minutesActual autonomy
EnvironmentTemperature, altitude, dust and ventilationLife and derating
InterfaceMonitoring, bypass, parallel requirementIntegration with the room
DocumentationConformity route and model test reportCustoms and tender
Applications

Where this family fits.

These are the load types the platform is specified for. If your load is outside this list, send the load profile before selecting the model.

  • Large UPS battery banks
  • Telecom sites
  • Substations
  • Solar storage
  • Industrial backup
FAQ

Specialty battery: project questions.

Project-specific answers. If your question is not here, send the load list and the site conditions.

Talk to an engineer

When should I use 2 V cells instead of 12 V blocks?

Use 2 V cells for large strings and long runtime, where the current per cell is high and the battery room can support a rack. 12 V blocks are simpler for small and medium systems.

Can I mix 2 V and 12 V blocks in one string?

No. A string must use the same cell type, capacity, and age. Mixing causes uneven charging and early failure.

Do the 48 V lithium modules need a special charger?

Yes. The charger must follow the lithium voltage profile and the BMS limits. A lead-acid charger is not a safe substitute.

How is the battery rack sized?

The rack is sized by the number of cells, the weight, the clearance, and the floor loading. Share the string layout for a rack recommendation.

Can you supply the battery monitor?

Yes, battery monitoring and inspection options are available for large strings. The sensor set depends on the string size and the monitoring platform.

Next step

Send the load list. We will return the configuration.

Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.

  • Capacity and topology recommendation
  • Battery bank and runtime estimate
  • Model sheet and commercial offer

Request a configuration and quotation

Send the load list, backup time, and site conditions. We will return a capacity recommendation, battery configuration, and commercial offer.

By submitting this form you agree to our privacy policy. Privacy policy

Published Last updated Specifications and certification are confirmed per project.