Skip to content
UPS Industrial frame · 10–200 kVA

Industrial UPS

Wide input, high overload, and harsh-environment protection.

  • 10–200 kVA
  • Wide input
  • IP21

Rated capacity

10–200 kVA

Input range

165–280 VAC (Ph-N) / 285–485 VAC (Ph-Ph)

Overload

150–180% for 1 h to 30 s, by magnitude

Industrial UPS cabinet with front display in a production facility

Rated range

10–200 kVA

Rated capacity
10–200 kVA
Input range
165–280 VAC (Ph-N) / 285–485 VAC (Ph-Ph)
Overload
150–180% for 1 h to 30 s, by magnitude
Protection
IP21
Operating temperature
0–55 °C on selected frames
Battery bus
384 VDC (large frames)
TL;DR

An industrial UPS from 10 to 200 kVA with a wide input window, high overload capability and IP21 protection, built for electrical rooms, process lines and plant loads rather than an IT closet. The wide input tolerance is what keeps it on mains where a commercial UPS would cycle on battery.

Overview

What this platform is built to do.

Industrial UPS systems are specified for the electrical room, not the IT closet. The load may be a PLC rack, a DCS, a CNC line, a packaging machine, or a water-treatment control panel. The input may come from a weak transformer, a generator, or a feeder shared with welding equipment. The UPS must ride through voltage sags, frequency swings, and high inrush without transferring to bypass.

The industrial frame accepts 165–280 VAC phase-neutral and 285–485 VAC line-line, which covers deep sags and generator overshoot. Output voltage is regulated to ±1% and the inverter supports 150–180% overload for 1 hour down to 30 seconds, depending on the magnitude. The enclosure is IP21 with forced ventilation, and the operating temperature range extends to 55 °C on selected frames.

For motor and compressor loads, size the UPS for starting current and load steps, not just running kW. A 3:1 crest factor covers many electronic loads, but a direct-on-line motor can draw 5–7 times rated current. Share the motor nameplate, starting method, and the largest step change when requesting a configuration.

Wide input tolerance

Rides through deep sags and generator swings without dropping to bypass.

High overload

Handles motor starting and load steps that would trip a commercial UPS.

Industrial protection

IP21 enclosure, forced cooling, and 0–55 °C operating range.

Project engineering

Breaker, cable, battery, and bypass coordination for the electrical room.

Industrial UPS cabinet
Industrial UPS cabinet
Three-phase industrial UPS cabinets
Three-phase industrial UPS cabinets
UPS cabinets in a test bay
UPS cabinets in a test bay
Models & specifications

Industrial frame · 10–200 kVA

Selected models and nominal values. The quotation confirms the exact configuration, battery, and documentation for the project.

Request a model sheet

Industrial UPS ratings

CapacityReal powerInput rangeBattery busTypical load
10 kVA8 kW165–280 VAC (Ph-N)384 VDCPLC rack / control room
20 kVA16 kW165–280 VAC (Ph-N)384 VDCPackaging line
30 kVA24 kW165–280 VAC (Ph-N)384 VDCWater treatment panel
60 kVA48 kW165–280 VAC (Ph-N)384 VDCProcess control / DCS
100 kVA80 kW165–280 VAC (Ph-N)384 VDCPlant-wide control
160 kVA128 kW165–280 VAC (Ph-N)384 VDCHeavy process line
200 kVA160 kW165–280 VAC (Ph-N)384 VDCLarge industrial facility

Input

Voltage
380/400 VAC, 3-phase + neutral
Voltage range
165–280 VAC (Ph-N); 285–485 VAC (Ph-Ph)
Frequency
46–64 Hz
Input PF
> 0.99
Generator compatibility
Confirm generator kVA and load step

Output

Voltage
380/400 VAC, 3-phase + neutral
Voltage accuracy
±1% balanced load
Frequency
50/60 Hz ±1%
THD
< 2% linear; < 5% at PF 0.8 non-linear
Overload
110–150% 10 min–60 s; >160% 200 ms
Transfer time
0 ms (sync)

Environment and protection

Operating temperature
0–55 °C
Storage temperature
−15–60 °C
Altitude
0–1,000 m without derating
Humidity
5–95% non-condensing
Protection
IP21
Cooling
Forced air

Key specifications

ParameterValue
Rated capacity10–200 kVA
Input range165–280 VAC (Ph-N) / 285–485 VAC (Ph-Ph)
Overload150–180% for 1 h to 30 s, by magnitude
ProtectionIP21
Operating temperature0–55 °C on selected frames
Battery bus384 VDC (large frames)

Selection notes for this family

QuestionWhat to checkWhy
Load profileRunning kW and largest step for 10–200 kVAAvoid overload and oversizing
RuntimeBattery bank and charger for the target minutesActual autonomy
EnvironmentTemperature, altitude, dust and ventilationLife and derating
InterfaceMonitoring, bypass, parallel requirementIntegration with the room
DocumentationConformity route and model test reportCustoms and tender
Applications

Where this family fits.

These are the load types the platform is specified for. If your load is outside this list, send the load profile before selecting the model.

  • PLC and DCS rooms
  • CNC and machining lines
  • Water and wastewater plants
  • Packaging and filling lines
  • Oil, gas, and petrochemical control
  • Steel and cement plants
FAQ

Industrial UPS: project questions.

Project-specific answers. If your question is not here, send the load list and the site conditions.

Talk to an engineer

Can an industrial UPS start a motor directly?

It can support a motor start within its overload window, but direct-on-line starting can draw 5–7 times rated current. Share the motor nameplate, starting method, and the largest step change; a soft starter or VFD may be the better solution.

Why does the input range matter?

A weak feeder may sag to 165 VAC phase-neutral during a motor start or a generator block load. A wider input range keeps the UPS on mains longer and preserves battery for real outages.

Is IP21 enough for a dusty plant?

IP21 protects against fingers and vertical drips, not fine dust. For dusty or corrosive environments, specify a filtered cabinet, positive pressure, or a higher IP rating with the panel builder.

Can the UPS be installed in a non-air-conditioned room?

Selected frames operate to 55 °C, but battery life falls sharply above 25 °C. Keep the battery in a cooler location or use a temperature-compensated charger and a derated battery bank.

Does the UPS support a maintenance bypass?

Yes, an external maintenance bypass is recommended for industrial installations so the UPS can be serviced without interrupting the load. The bypass must be interlocked with the UPS output.

Next step

Send the load list. We will return the configuration.

Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.

  • Capacity and topology recommendation
  • Battery bank and runtime estimate
  • Model sheet and commercial offer

Request a configuration and quotation

Send the load list, backup time, and site conditions. We will return a capacity recommendation, battery configuration, and commercial offer.

By submitting this form you agree to our privacy policy. Privacy policy

Published Last updated Specifications and certification are confirmed per project.