Every family. Every model table. One page.

The complete catalogue as configured from the source catalogues: 28 product families and their model ranges. Use this page to locate a series, then open the family page for the full specification and selection guidance.

Full product model range
Product families
30
Model rows
257
Categories
7
Power envelope
0.5–2000 kVA
UPS systems

12 families

Back to catalogue

UPS · MT / HI11 / AP / AK · 500 VA – 5 kVA

Line-Interactive UPS

Compact, AVR-corrected backup for POS, security, and office loads.

Family page
ModelCapacityReal powerBatteryDimensions (mm)Net weight
MT-500500 VA300 W12 V 4.5 Ah × 1280 × 90 × 1404.0 kg
MT-650650 VA390 W12 V 7 Ah × 1320 × 90 × 1405.2 kg
MT-800800 VA480 W12 V 9 Ah × 1330 × 100 × 1505.7 kg
MT-10001,000 VA600 W12 V 7 Ah × 2365 × 140 × 16510 kg
MT-15001,500 VA900 W12 V 9 Ah × 2365 × 140 × 16511.9 kg
MT-20002,000 VA1,200 W12 V 9 Ah × 2365 × 140 × 16512.6 kg
MT-2000B2,000 VA1,200 W12 V 7 Ah × 4395 × 145 × 21017 kg
MT-30003,000 VA1,800 W12 V 9 Ah × 4395 × 145 × 21021 kg
HI11-600VA600 VASeries-dependent12 V internalSeries-dependentSeries-dependent
HI11-1200VA1,200 VASeries-dependent12 V internalSeries-dependentSeries-dependent
HI11-2KVA2,000 VASeries-dependent24 V internalSeries-dependentSeries-dependent
HI11-3KVA3,000 VASeries-dependent24 V internalSeries-dependentSeries-dependent
HI11-4KVA4,000 VASeries-dependent48 V internalSeries-dependentSeries-dependent
HI11-5KVA5,000 VASeries-dependent48 V internalSeries-dependentSeries-dependent
AP1000VA1,000 VASeries-dependent24 V externalSeries-dependentSeries-dependent
AP2000VA2,000 VASeries-dependent48 V externalSeries-dependentSeries-dependent
AP3000VA3,000 VASeries-dependent48 V externalSeries-dependentSeries-dependent
AK500VA500 VASeries-dependent12 V internalSeries-dependentSeries-dependent
AK650VA650 VASeries-dependent12 V internalSeries-dependentSeries-dependent
AK800VA800 VASeries-dependent12 V internalSeries-dependentSeries-dependent
AK1000VA1,000 VASeries-dependent12 V internalSeries-dependentSeries-dependent
AK1500VA1,500 VASeries-dependent24 V internalSeries-dependentSeries-dependent
AK2000VA2,000 VASeries-dependent24 V internalSeries-dependentSeries-dependent
AK3000VA3,000 VASeries-dependent24 V internalSeries-dependentSeries-dependent

MT series models and nominal specifications

UPS · YT Series · 1–10 kVA

Single-Phase Online UPS

Double-conversion, 0 ms protection for servers, medical, and telecom loads.

Family page
ModelCapacityReal powerDC busFormatBattery
YT1K1 kVA900 W24 VTowerInternal 12 V 7 Ah × 2
YT2K2 kVA1,800 W48 VTowerInternal 12 V 7 Ah × 4
YT3K3 kVA2,700 W72 VTowerInternal 12 V 7 Ah × 6
YT6K6 kVA5,400 W144 VTowerInternal 12 V 7 Ah × 12
YT10K10 kVA9,000 W192/240 VTowerInternal 12 V 7 Ah × 16–20
YT1KR1 kVA800 W24 VRackInternal 12 V 7 Ah × 2
YT2KR2 kVA1,600 W48 VRackInternal 12 V 7 Ah × 4
YT3KR3 kVA2,400 W72 VRackInternal 12 V 7 Ah × 6
YT6KRS6 kVA5,400 W192/240 VRackExternal
YT10KRS10 kVA9,000 W192/240 VRackExternal

YT series single-phase online UPS models

UPS · 3YT / GP Series · 10–200 kVA

Three-Phase Online UPS

Three-phase double conversion for facility and industrial loads.

Family page
Model familyCapacity rangeOutput PFBattery busTypical application
3YT 10–20 kVA10 / 15 / 20 kVA0.9192/240 VDCServer room, clinic, branch DC
3YT 30–60 kVA30 / 40 / 50 / 60 kVA0.9384 VDCData center, industrial line
3YT 80–120 kVA80 / 100 / 120 kVA0.9384 VDCPlant, telecom core, hospital
GP 30–200 kVA30–200 kVA0.8–0.9384 VDCLarge facility, process plant
Parallel framesUp to 4–6 units0.9Shared batteryN+1 or capacity expansion
GP3310–200 kVA0.9384 VDCThree-phase facility load
GP3110–40 kVA0.9192/240 VDC3-phase in / 1-phase out
GP116–10 kVA0.9192/240 VDCSingle-phase IT room
HP3330–200 kVA0.9384 VDCHigh-frequency three-phase
HP3110–20 kVA0.9192/240 VDC3-phase in / 1-phase out
HP111–10 kVA0.9192/240 VDCSingle-phase high-frequency

Three-phase online UPS frames and power ratings

UPS · YT-R / UM / RT · 1–60 kVA

Rack-Mount UPS

Double conversion in 1U–3U, built for racks and edge rooms.

Family page
ModelCapacityReal powerDC busFormatBattery
YT1KR1 kVA800 W24 V1U / 2UInternal
YT2KR2 kVA1,600 W48 V2UInternal
YT3KR3 kVA2,400 W72 V2U / 3UInternal
YT6KRS6 kVA5,400 W192/240 V3UExternal
YT10KRS10 kVA9,000 W192/240 V3UExternal
UM-1KR1 kVA800 W24 V1UInternal
UM-2KR2 kVA1,600 W48 V2UInternal
UM-3KR3 kVA2,400 W72 V2U / 3UInternal
RT33-10K–60K10–60 kVA9–54 kW384 VDCRackExternal
RT11-1K–10K1–10 kVA0.8–9 kW24–192 VDCRackInternal / external

Rack-mount online UPS models

UPS · Modular frames · 10–600 kVA

Modular UPS

Scale capacity and redundancy one hot-swappable module at a time.

Family page
FrameRated powerModule capacityModule slotsTypical redundancy
5U-9090 kW / 60 kW30 kW / 20 kW3N+1 with 3 × 30 kW
30U-9090 kW30 kW3N+1
42U-120120 kW30 kW4N+1
30U-180180 kW30 kW6N+1 / N+2
42U-200200 kW30 kW10N+1
42U-210210 kW30 kW7+1N+1
42U-300300 kW30 kW10N+1
MK60-P2060 kVA20 kW3N+1
MK90-P3090 kVA30 kW3N+1
MK120-P40120 kVA40 kW3N+1
MK100-P20100 kVA20 kW5N+1
MK150-P30150 kVA30 kW5N+1
MK200-P40200 kVA40 kW5N+1
MK200-P20200 kVA20 kW10N+1
MK300-P30300 kVA30 kW10N+1
MK400-P40400 kVA40 kW10N+1

Modular UPS frame configurations

UPS · Industrial frame · 10–200 kVA

Industrial UPS

Wide input, high overload, and harsh-environment protection.

Family page
CapacityReal powerInput rangeBattery busTypical load
10 kVA8 kW165–280 VAC (Ph-N)384 VDCPLC rack / control room
20 kVA16 kW165–280 VAC (Ph-N)384 VDCPackaging line
30 kVA24 kW165–280 VAC (Ph-N)384 VDCWater treatment panel
60 kVA48 kW165–280 VAC (Ph-N)384 VDCProcess control / DCS
100 kVA80 kW165–280 VAC (Ph-N)384 VDCPlant-wide control
160 kVA128 kW165–280 VAC (Ph-N)384 VDCHeavy process line
200 kVA160 kW165–280 VAC (Ph-N)384 VDCLarge industrial facility

Industrial UPS ratings

UPS · GP / GF / GS / GI / GL / MS · 400 VA – 3 kVA

Offline UPS

Standby backup for routers, POS, desktops, and small security loads.

Family page
SeriesCapacity rangeBattery busWaveformTypical use
GP400–2,000 VA12 / 24 VSimulated sineRouter, desktop, POS
GF400–1,000 VA12 VSimulated sineSmall office, CCTV
GS400–3,000 VA12 / 24 VSimulated sineOffice IT, access control
GS BI400–2,000 VA12 / 24 VSimulated sineBackup with AVR
GI600–1,200 VA12 VSimulated sineCompact IT
GL1,000–2,000 VA24 VSimulated sineBranch office
GSC400–2,000 VA12 / 24 VSimulated sineRetail / POS
MU1,000–3,000 VA24 / 48 VSimulated sineLong-run small load
MS600–3,000 VA12 / 24 VPure sineSensitive small loads

Offline UPS series and capacity ranges

UPS · HH / HL / PHR / DL · 1–800 kVA

High-Frequency Online UPS

Transformerless online UPS for IT rooms, telecom, and industrial projects.

Family page
SeriesCapacityInput / outputFormatTypical use
HH111–10 kVA1-phase / 1-phaseTowerServer room, branch IT
HH3110–20 kVA3-phase / 1-phaseTowerSmall DC, clinic
HH3310–80 kVA3-phase / 3-phaseTowerData center, plant
PHR1–10 kVA1-phase / 1-phaseRackEdge rack
HL112–20 kVA1-phase / 1-phaseTowerIT room
HL316–80 kVA3-phase / 1-phaseTowerFacility load
HL3310–200 kVA3-phase / 3-phaseTowerData center
DL3–80 kVA1/3-phaseCompact towerSmall project
Giant iND10–800 kVA3-phase / 3-phaseIndustrial frameIndustrial plant
UT II10–200 kVA3-phase / 3-phaseTowerHigh-frequency online
UT III30–200 kVA3-phase / 3-phaseTowerHigh-frequency online
+Power40–180 kVA3-phase / 3-phaseModular frameData center / facility
S series10–200 kVA3-phase / 3-phaseTowerHigh-frequency online
S 250–800 kVA250–800 kVA3-phase / 3-phaseLarge frameLarge facility

High-frequency online UPS series

UPS · NX Series · 10–600 kVA

NX Modular UPS

X+N redundancy, hot-swap modules, and a 600 kVA parallel ceiling.

Family page
ConfigurationFrame capacityParallel ceilingModule optionsTypical use
Single frame10–300 kVA600 kVA with two frames10–50 kVA modulesServer room / small DC
X+N frame10–300 kVA600 kVA10–50 kVA modulesN+1 data center
Parallel frames2 × 300 kVA600 kVA10–50 kVA modulesLarge data center
Micro-module integrated30–600 kVA600 kVA10–50 kVA modulesPrefabricated room

NX modular frame configurations

UPS · AD-ARD Series · 7.5–30 kW

Elevator UPS

Dedicated backup for elevator controls and rescue operation.

Family page
ModelControl capacityTraction machineInputBattery
AD-ARD-2P075-41,000 VA7.5 kW3-phase12 V 7 Ah × 2
AD-ARD-2P110-41,250 VA11 kW3-phase12 V 7 Ah × 3
AD-ARD-2P150-41,500 VA15 kW3-phase12 V 9 Ah × 3
AD-ARD-2P220-42,200 VA22 kW3-phase12 V 9 Ah × 4
AD-ARD-3P185-42,000 VA18.5 kW3-phase12 V 7 Ah × 7
AD-ARD-3P300-43,000 VA30 kW3-phase12 V 7 Ah × 8

AD-ARD elevator UPS models

UPS · POE Series · 17–120 W

Mini DC UPS

Compact DC/PoE backup for routers, cameras, and CPE — B2B only.

Family page
ModelOutput powerOutputsBatteryTypical use
POE-532E17 WUSB, 5/9/12 V, 15/24 V PoELi-ion 2200 mAh × 4Router / ONT
POE-30N30 WUSB, 5/9/12 V, 15/24 V PoELi-ion 2200 mAh × 4Router / camera
POE-830P-LFP18 WUSB/Type-C, DC, 24 V PoELiFePO4 5000 mAh × 4CPE / camera
POE-930P-LFP18 WUSB/Type-C, DC, 24 V PoELiFePO4 6000 mAh × 4CPE / camera
POE-36E-LFP-48V36 W48 V PoELiFePO4PoE camera
MINIPOE-60W60 WDC + PoELi-ion 2200 mAh × 8High-power CPE
POE-45N45 WDC + PoELi-ion 2200 mAh × 4Camera / CPE
POE-G110110 WDC + PoELi-ion 2200 mAh × 8Camera / CPE
POE-120WP-LFP120 WDC + PoELiFePO4 5000 mAh × 4Camera / CPE
B600T-1212 V / 60 W12 V DCLi-ion 2200 mAh × 6Router / CPE
B600T-1919 V / 60 W19 V DCLi-ion 2200 mAh × 6Router / CPE
B600T-2424 V / 72 W24 V DCLi-ion 2200 mAh × 6Router / CPE

Mini DC UPS models

UPS · ULi 3KL–6KL · 3–6 kVA

Lithium UPS

48 V lithium rack UPS with 0 ms transfer and a 60 A charger.

Family page
ModelCapacityReal powerBattery busDimensionsWeight
ULi 3KL-48V CN3,000 VA3,000 W40–64 VDC420 × 438 × 132.5 mm15 kg
ULi 5KL-48V CN5,000 VA5,000 W40–64 VDC420 × 438 × 132.5 mm15 kg
ULi 6KL-48V CN6,000 VA5,100 W40–64 VDC420 × 438 × 132.5 mm15 kg

ULi lithium UPS models

Voltage stabilizers

6 families

Back to catalogue

Voltage stabilizer · SVC Series · 0.5–100 kVA

Servo Voltage Stabilizer

±2% output from a 160–456 V input swing.

Family page
ModelPhaseCapacityInput rangeOutputDimensions (mm)Weight
SVC-500VA1-phase0.5 kVA / 0.4 kW150–260 VAC220 VAC ±3%190 × 170 × 1405 kg
SVC-1KVA1-phase1 kVA / 0.8 kW150–260 VAC220 VAC ±3%200 × 200 × 1606 kg
SVC-1.5KVA1-phase1.5 kVA / 1.2 kW150–260 VAC220 VAC ±3%200 × 200 × 1607 kg
SVC-2KVA1-phase2 kVA / 1.6 kW150–260 VAC220 VAC ±3%270 × 250 × 2009 kg
SVC-3KVA1-phase3 kVA / 2.4 kW150–260 VAC220 VAC ±3%300 × 240 × 23011 kg
SVC-5KVA1-phase5 kVA / 4 kW150–260 VAC220 VAC ±3%320 × 240 × 28016 kg
SVC-10KVA-S1-phase10 kVA / 8 kW160–260 VAC220 VAC ±2%350 × 400 × 65055 kg
SVC-15KVA-S1-phase15 kVA / 12 kW160–260 VAC220 VAC ±2%350 × 400 × 65070 kg
SVC-20KVA-S1-phase20 kVA / 16 kW160–260 VAC220 VAC ±2%380 × 450 × 75590 kg
SVC-30KVA-S1-phase30 kVA / 24 kW160–260 VAC220 VAC ±2%380 × 450 × 755130 kg
SVC-10KVA-T3-phase10 kVA / 8 kW304–456 VAC380/400/415 VAC ±2%380 × 450 × 75555 kg
SVC-15KVA-T3-phase15 kVA / 12 kW304–456 VAC380/400/415 VAC ±2%380 × 450 × 75560 kg
SVC-20KVA-T3-phase20 kVA / 16 kW304–456 VAC380/400/415 VAC ±2%400 × 650 × 760102 kg
SVC-30KVA-T3-phase30 kVA / 24 kW304–456 VAC380/400/415 VAC ±2%400 × 650 × 760118 kg
SVC-40KVA-T3-phase40 kVA / 32 kW304–456 VAC380/400/415 VAC ±2%450 × 700 × 850130 kg
SVC-50KVA-T3-phase50 kVA / 40 kW304–456 VAC380/400/415 VAC ±2%450 × 700 × 850145 kg
SVC-60KVA-T3-phase60 kVA / 48 kW304–456 VAC380/400/415 VAC ±2%450 × 700 × 850160 kg
SVC-80KVA-T3-phase80 kVA / 64 kW304–456 VAC380/400/415 VAC ±2%450 × 600 × 1,000200 kg
SVC-100KVA-T3-phase100 kVA / 80 kW304–456 VAC380/400/415 VAC ±2%520 × 700 × 1,200230 kg

SVC series single-phase and three-phase models (0.5–100 kVA)

Voltage stabilizer · KPD Series · 10–30 kVA

Contact-Type Voltage Stabilizer

±1% precision from a carbon-brush autotransformer.

Family page
ModelCapacityInputOutputLoad currentDimensions
KPD-10KVA10 kVA220 V ±20%220 V ±1%45 AConfirm with datasheet
KPD-15KVA15 kVA220 V ±20%220 V ±1%68 AConfirm with datasheet
KPD-30KVA30 kVA220 V ±20%220 V ±1%136 AConfirm with datasheet

KPD contact-type stabilizer models

Voltage stabilizer · SVC-T Series · 10–100 kVA

Three-Phase Voltage Stabilizer

Independent phase regulation for unbalanced three-phase loads.

Family page
ModelCapacityInput rangeOutputDimensions (mm)Weight
SVC-10KVA-T10 kVA304–456 VAC380/400/415 VAC ±2%380 × 450 × 75555 kg
SVC-15KVA-T15 kVA304–456 VAC380/400/415 VAC ±2%380 × 450 × 75560 kg
SVC-20KVA-T20 kVA304–456 VAC380/400/415 VAC ±2%400 × 650 × 760102 kg
SVC-30KVA-T30 kVA304–456 VAC380/400/415 VAC ±2%400 × 650 × 760118 kg
SVC-40KVA-T40 kVA304–456 VAC380/400/415 VAC ±2%450 × 700 × 850130 kg
SVC-50KVA-T50 kVA304–456 VAC380/400/415 VAC ±2%450 × 700 × 850145 kg
SVC-60KVA-T60 kVA304–456 VAC380/400/415 VAC ±2%450 × 700 × 850160 kg
SVC-80KVA-T80 kVA304–456 VAC380/400/415 VAC ±2%450 × 600 × 1,000200 kg
SVC-100KVA-T100 kVA304–456 VAC380/400/415 VAC ±2%520 × 700 × 1,200230 kg

SVC-T three-phase models

Voltage stabilizer · SBW Series · 10–2000 kVA

SBW Servo Stabilizer

Heavy-duty servo stabilization for large industrial and medical loads.

Family page
Model groupCapacityPhaseInput rangeTypical use
SBW-10KVA-S10 kVASingle176–264 VACSmall industrial load
SBW-20KVA-S20 kVASingle176–264 VACClinic / workshop
SBW-30KVA-S30 kVASingle176–264 VACProduction line
SBW-50KVA-T50 kVAThree304–456 VACFactory section
SBW-100KVA-T100 kVAThree304–456 VACPlant / building
SBW-200KVA-T200 kVAThree304–456 VACLarge plant
SBW-500KVA-T500 kVAThree304–456 VACHeavy industry
SBW-1000KVA-T1000 kVAThree304–456 VACPlant-wide
SBW-2000KVA-T2000 kVAThree304–456 VACLarge industrial site

SBW series capacity range

Voltage stabilizer · ZBW Series · 10–2000 kVA

ZBW Static Stabilizer

No moving parts, fast correction, and a wide industrial range.

Family page
Model groupCapacityInputOutputTypical use
ZBW-10KVA-T10 kVA304–456 VAC380/400/415 VAC ±2%Small plant
ZBW-30KVA-T30 kVA304–456 VAC380/400/415 VAC ±2%Production line
ZBW-50KVA-T50 kVA304–456 VAC380/400/415 VAC ±2%Factory section
ZBW-100KVA-T100 kVA304–456 VAC380/400/415 VAC ±2%Building / plant
ZBW-200KVA-T200 kVA304–456 VAC380/400/415 VAC ±2%Large facility
ZBW-300KVA-T300 kVA304–456 VAC380/400/415 VAC ±2%Heavy industry
ZBW-1000KVA-T1000 kVA304–456 VAC380/400/415 VAC ±2%Plant-wide
ZBW-2000KVA-T2000 kVA304–456 VAC380/400/415 VAC ±2%Large industrial site

ZBW series capacity range

Voltage stabilizer · AD-DTS / KPBS / JJW / JSW · 1–600 kVA

Industrial AVR

Application-specific AVRs for plants, CNC, and precision equipment.

Family page
SeriesCapacityPhaseTypical useNotes
AD-DTS10–100 kVAThreePlant / building incomingThree-phase AVR
KPBS50–600 kVAThreeHeavy industrial loadHigh-power frame
LHD-C1–3 kVASingleLab / precision benchContactless
JJW1–30 kVASingleSmall machine / officeCompact AVR
JSW3–80 kVAThreeWorkshop / production lineThree-phase AVR
CNC AVRModel-specificSingle / threeCNC machineMachine-integrated

Industrial AVR series

Battery systems

3 families

Back to catalogue

Battery · 12 V blocks · 24–250 Ah

VRLA Battery

Maintenance-free sealed lead-acid blocks for UPS and telecom backup.

Family page
ModelVoltageCapacityWeightDimensions (L × W × H)Terminal
KYT12-24Ah12 V24 Ah7.5 kg166 × 126 × 174 mmT14/T5
KYT12-33Ah12 V33 Ah10 kg195 × 130 × 155 mmT14/T6
KYT12-50Ah12 V50 Ah16.2 kg230 × 138 × 211 mmT14
KYT12-65Ah12 V65 Ah20.4 kg350 × 166 × 179 mmT14
KYT12-100Ah12 V100 Ah29.5 kg330 × 171 × 214 mmT16
KYT12-120Ah12 V120 Ah34.8 kg409 × 176 × 225 mmT16
KYT12-150Ah12 V150 Ah41.8 kg485 × 172 × 240 mmT16
KYT12-200Ah12 V200 Ah59.5 kg522 × 238 × 218 mmT16
KYT12-250Ah12 V250 Ah71.5 kg521 × 269 × 220 mmT16

KYT12 series VRLA 12 V blocks (selected models)

Battery · 51.2 V rack · 50–280 Ah

LiFePO4 Battery

More usable cycles and less weight for long runtime.

Family page
ModelVoltageCapacityEnergyDimensions (mm)Weight
YT-485051.2 V50 Ah2.56 kWh440 × 484 × 8827 kg
YT-48100 (48 V)48 V100 Ah4.8 kWh440 × 484 × 17841 kg
YT-48100 (51.2 V)51.2 V100 Ah5.12 kWh440 × 484 × 17845 kg
YT-48200 (48 V)48 V200 Ah9.6 kWh440 × 796 × 17874 kg
YT-48200 (51.2 V)51.2 V200 Ah10.24 kWh440 × 796 × 17878 kg
YT-48280 (51.2 V)51.2 V280 Ah14.336 kWh405 × 750 × 230105 kg

Rack LiFePO4 module range

Battery · 2 V / 12 V / 48 V · 4–2000 Ah

Specialty Battery Systems

Long-duration lead-acid and lithium blocks for large backup systems.

Family page
ModelVoltageCapacityTypeTypical use
AD12-10012 V100 AhVRLAUPS / solar
AD12-20012 V200 AhVRLATelecom / UPS
AJ2-5002 V530 AhVRLALarge UPS string
AJ2-10002 V1060 AhVRLASubstation / plant
AJ2-20002 V2120 AhVRLALong-duration bank
48V50AH48 V50 AhLiFePO4Rack / hybrid
48V100AH48 V100 AhLiFePO4Rack / hybrid

Specialty battery models

Inverters

2 families

Back to catalogue

Inverter · SP Series · 2.2–7 kVA

Pure Sine Wave Inverter

Grid or solar charging with a pure sine wave output.

Family page
ModelRated powerDC voltageMPPT PVSurge powerWeight
SP-22002,200 VA / 1,800 W12 VDC2,000 W4,400 VA4.5 kg
SP-32003,200 VA / 3,000 W24 VDC3,000 W6,400 VA5.0 kg
SP-40004,000 VA / 3,600 W24 VDC5,000 W8,000 VA7.0 kg
SP-70007,000 VA / 6,200 W48 VDC6,000 W14,000 VA8.0 kg

SP series inverter models

Inverter · ESSM / PV Series · 1–6.2 kW

Hybrid & Storage Inverter

Solar, grid, and battery in one cabinet.

Family page
ModelPowerBatteryTypeTypical use
ESSM-1.0KW-100AH1.0 kW12.8 V 100 AhHybridSmall home / clinic
ESSM-1.5KW-100AH1.5 kW12.8 V 100 AhHybridHome / shop
ESSM-4.2KW-100AH4.2 kW51.2 V 100 AhHybridHome / office
ESSM-6.2KW-100AH6.2 kW51.2 V 100 AhHybridCommercial
PV-3024D3 kW24 VHybridHome / telecom
PV-50485 kW48 VHybridHome / clinic
PV-60486 kW48 VHybridCommercial

Hybrid inverter models

Emergency power

2 families

Back to catalogue

Emergency power · ST-D / ST-DS / EPS YJ · 0.5–500 kVA

EPS Emergency Power Supply

Fire-code emergency power for lighting, pumps, and safety loads.

Family page
SeriesPowerPhaseBattery busTypical load
ST-D 0.5–3 kW0.5–3 kWSingle48 VDCEmergency lighting
ST-D 4–15 kW4–15 kWSingle192 VDCFire pump / lighting
ST-DS 2–18.5 kW2–18.5 kWThree192 VDCSmoke control / pump
ST-DS 20–55 kW20–55 kWThree324 VDCLarge safety load
ST-DS 60+ kW60+ kWThree492 VDCPlant emergency power
EPS II 3K-48V3 kWSingle48 VDCEmergency lighting
EPS II 5K-48V5 kWSingle48 VDCEmergency lighting
EPS II 6K-48V6 kWSingle48 VDCEmergency lighting
EPS-YJ-22–500 kVAThreeModel-dependentProject emergency power

EPS series

Emergency power · C-1812 System · DC24/36 V

Fire Emergency Lighting

Central power, controllers, and evacuation signage as one system.

Family page
ComponentModel / typeSpecificationUse
ControllerC-1812Central monitoring and testBuilding system
Exit signDC24/36 VFlag or box signEgress route
Emergency downlightDC24/36 VCeiling luminaireCorridor / room
Dual-head lightDC24/36 VTwin headStair / hall

Emergency lighting system components

Data center infrastructure

3 families

Back to catalogue

Data center infrastructure · ADS / AD Series · 3.5–110 kW

Precision Air Conditioner

Room-level and row-level cooling for data and equipment rooms.

Family page
SeriesCapacityFormatTypical roomNotes
ADS-025–04225–42 kWRoom-levelSmall data centerAir-cooled
ADS-052–07252–72 kWRoom-levelMedium data centerAir / chilled water
ADS-082–10282–102 kWRoom-levelLarge data centerAir / chilled water
AD-3.5–12.53.5–12.5 kWRow / wallEdge roomCompact

Precision AC capacity range

Data center infrastructure · Pool-level / row-level · 20–600 kVA

Micro-Module Data Center

Prefabricated power, cooling, racks, and monitoring in one footprint.

Family page
ConfigurationRacksUPSCoolingTypical use
Pool-levelUp to 1030–600 kVA modular12.5–60 kW rowSmall / medium DC
Row-level2–1020–150 kVA modular3.5–12.5 kWEdge / branch DC
Rack UPS2–85–20 kVA rack3.5–12.5 kWSmall IT room
ExpansionAdd racksAdd modulesAdd coolingPhased build

Micro-module configurations

Data center infrastructure · YG / YGD · 0.5–500 kVA

Remote Power Supply

Long-distance AC and DC power transmission for remote sites.

Family page
SeriesCapacityInputOutputApplication
YG-7.57.5 kVA220/380 VAC660–3300 VACRemote village
YG-5050 kVA220/380 VAC660–3300 VACTelecom / mining
YG-200200 kVA220/380 VAC660–3300 VACLarge remote site
YG-500500 kVA220/380 VAC660–3300 VACIndustrial transmission
YGD-0.50.5 kVA660–3300 VDC220 VACSmall remote load
YGD-1212 kVA660–3300 VDC220 VACRemote downstream unit
YGD-200200 kVA660–3300 VDC220 VACLarge DC transmission
Head/remote10–100 / 0.5–12 kVAAC / DC linkDC / ACDistributed site

YG / YGD remote power series

Power quality

2 families

Back to catalogue

Power quality · BK / SG / OSG / YG · 25 VA–500 kVA

Transformers & Reactors

Isolation, voltage conversion, and harmonic filtering for power systems.

Family page
SeriesCapacity / modelTypeTypical use
BK25 VA–10 kVASingle-phase controlControl / small load
SG1–500 kVAThree-phase dryIsolation / conversion
OSG1–100 kVAThree-phase dryIsolation
YG0.5–500 kVAThree-phaseIndustrial supply
PV reactorInverter-matchedReactorPV inverter
Siemens reactorS11-RCTReactorSiemens drive
Fanuc reactorA81LReactorFanuc drive
Servo electronic transformerModel-dependentSingle / threeCNC servo matching

Transformer and reactor series

Power quality · TPS / AFC · 0.5–1000 kVA

Frequency Converters

50/60/400 Hz power for aviation, marine, and test benches.

Family page
SeriesCapacityPhaseFrequencyTypical use
TPS-61005500 VASingle50/60/400 HzBench test
TPS-61011 kVASingle50/60/400 HzLab / export equipment
TPS-61022 kVASingle50/60/400 HzLab / aviation
CSJ-500W500 VASingle50/60/400 HzTest bench
TPS633–600 kVAThree50/60/400 HzIndustrial / marine
AFC5–1000 kVAThree40–499.9 HzLarge project
AdTroModel-dependentThree50/60/400 HzIndustrial VFD

Frequency converter models

Next step

Send the load list. We will return the configuration.

Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.

  • Capacity and topology recommendation
  • Battery bank and runtime estimate
  • Model sheet and commercial offer

Request a configuration and quotation