Skip to content
Voltage stabilizer SBW Series · 10–2000 kVA

SBW Servo Stabilizer

Heavy-duty servo stabilization for large industrial and medical loads.

  • 10–2000 kVA
  • ±2% output
  • Heavy duty

Single-phase

10–100 kVA

Three-phase

50–2000 kVA

Input range

176–264 VAC / 304–456 VAC

SBW servo stabilizer cabinets

Rated range

10–2000 kVA

Single-phase
10–100 kVA
Three-phase
50–2000 kVA
Input range
176–264 VAC / 304–456 VAC
Output accuracy
±2%
Efficiency
> 98%
Monitoring
RS485; LCD or touch LCD
TL;DR

An SBW servo stabilizer from 10 to 2000 kVA for plant-scale loads, correcting wide input swings with ±1–5% output accuracy. It is the frame used where a whole factory or building is regulated at the incoming supply.

Overview

What this platform is built to do.

The SBW series is a heavy-duty servo stabilizer for large industrial and commercial loads. It uses solid copper columns, a servo motor, and a precision control system to hold the output at ±2% while the input moves across a wide window.

Single-phase models cover 10–100 kVA; three-phase models cover 50–2000 kVA. The series is designed for laser cutting machines, elevators, machine tools, CT and MRI equipment, and other high-power loads that need a stable supply and a robust overload capability.

The controller uses DSP and offers a manual bypass, forced-air cooling, full protections, and RS485 monitoring. The SBW is a stabilizer, not a UPS: it corrects voltage but does not provide backup.

High-power capacity

Up to 2000 kVA for plant-wide and medical installations.

Robust construction

Solid copper columns and a servo drive built for harsh power environments.

Manual bypass

Service the stabilizer without interrupting the load.

RS485 monitoring

Remote voltage, current, and alarm data.

SBW stabilizer cabinets
SBW stabilizer cabinets
SBW internal transformer assembly
SBW internal transformer assembly
SBW control display
SBW control display
Models & specifications

SBW Series · 10–2000 kVA

Selected models and nominal values. The quotation confirms the exact configuration, battery, and documentation for the project.

Request a model sheet

SBW series capacity range

Model groupCapacityPhaseInput rangeTypical use
SBW-10KVA-S10 kVASingle176–264 VACSmall industrial load
SBW-20KVA-S20 kVASingle176–264 VACClinic / workshop
SBW-30KVA-S30 kVASingle176–264 VACProduction line
SBW-50KVA-T50 kVAThree304–456 VACFactory section
SBW-100KVA-T100 kVAThree304–456 VACPlant / building
SBW-200KVA-T200 kVAThree304–456 VACLarge plant
SBW-500KVA-T500 kVAThree304–456 VACHeavy industry
SBW-1000KVA-T1000 kVAThree304–456 VACPlant-wide
SBW-2000KVA-T2000 kVAThree304–456 VACLarge industrial site

Input and output

Single-phase
220 VAC, 176–264 VAC, 10–100 kVA
Three-phase
380/400/415 VAC, 304–456 VAC, 50–2000 kVA
Output accuracy
±2%
Response time
< 1 s for a 10% step
Efficiency
> 98%
Power factor
0.8

Protection and monitoring

Protections
Over/under voltage, overload, overcurrent, short circuit, phase loss, phase reversal
Manual bypass
Standard
Display
LCD or touch LCD
Communication
RS485 standard; Ethernet optional
Cooling
Forced ventilation

Key specifications

ParameterValue
Single-phase10–100 kVA
Three-phase50–2000 kVA
Input range176–264 VAC / 304–456 VAC
Output accuracy±2%
Efficiency> 98%
MonitoringRS485; LCD or touch LCD

Selection notes for this family

QuestionWhat to checkWhy
Load profileRunning kW and largest step for 10–2000 kVAAvoid overload and oversizing
RuntimeBattery bank and charger for the target minutesActual autonomy
EnvironmentTemperature, altitude, dust and ventilationLife and derating
InterfaceMonitoring, bypass, parallel requirementIntegration with the room
DocumentationConformity route and model test reportCustoms and tender
Applications

Where this family fits.

These are the load types the platform is specified for. If your load is outside this list, send the load profile before selecting the model.

  • Laser cutting machines
  • Machine tools
  • Elevators
  • CT and MRI
  • Large production lines
  • Plant-wide stabilization
FAQ

SBW stabilizer: project questions.

Project-specific answers. If your question is not here, send the load list and the site conditions.

Talk to an engineer

What is the difference between SBW and SVC?

Both are servo stabilizers. SBW is the heavy-duty range up to 2000 kVA with solid copper columns and a robust frame; SVC is the standard range up to 100 kVA with a more compact cabinet.

Can SBW run a CT or MRI?

It is specified for high-power medical equipment, but the exact model depends on the imaging system’s inrush and the room’s supply. Share the equipment datasheet before ordering.

Does SBW provide backup?

No. It corrects voltage but does not store energy. Add a UPS for outage ride-through.

Is the manual bypass included?

The SBW series includes a manual bypass for maintenance. Confirm the bypass configuration for your installation.

Can it be installed outdoors?

The standard enclosure is indoor-rated. For outdoor installation, use a protected enclosure with ventilation and the appropriate IP rating.

Next step

Send the load list. We will return the configuration.

Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.

  • Capacity and topology recommendation
  • Battery bank and runtime estimate
  • Model sheet and commercial offer

Request a configuration and quotation

Send the load list, backup time, and site conditions. We will return a capacity recommendation, battery configuration, and commercial offer.

By submitting this form you agree to our privacy policy. Privacy policy

Published Last updated Specifications and certification are confirmed per project.