Data center infrastructure ADS / AD Series · 3.5–110 kW

Precision Air Conditioner

Room-level and row-level cooling for data and equipment rooms.

  • 3.5–110 kW
  • Temperature + humidity
  • Row / room

Room-level

25–110 kW

Row / small room

3.5–12.5 kW

Cooling

Air-cooled or chilled water

Precision air conditioner cabinet

Rated range

3.5–110 kW

Room-level
25–110 kW
Row / small room
3.5–12.5 kW
Cooling
Air-cooled or chilled water
Control
Temperature and humidity
Refrigerant
R410A
Monitoring
RS485 / dry contacts
TL;DR

A precision air conditioner from 3.5 to 110 kW with temperature and humidity control, EC fans and RS485 monitoring, for data centres and equipment rooms. It holds set point continuously, which comfort split units cycle around and cannot guarantee.

Overview

What this platform is built to do.

The ADS and AD series are precision air conditioners for data centers, equipment rooms, and critical spaces. They control temperature and humidity within a tight band and run continuously, unlike a comfort air conditioner.

The range includes room-level units from 25 to 110 kW and smaller row/room units from 3.5 to 12.5 kW, with air-cooled or chilled-water options. The units use EC fans, R410A refrigerant, and a high-precision controller, and can be integrated with the room’s monitoring system.

Selection depends on the IT load, the room volume, the redundancy target, the heat rejection path, and the humidity requirement. Share the room dimensions, the IT load, and the ambient design conditions for a cooling layout.

Tight control

Temperature and humidity control for equipment rooms.

Continuous duty

Designed for 24/7 operation, not comfort cycling.

Row and room

Wall, row, and room-level formats for different densities.

Monitoring ready

RS485 and dry contacts for the room management system.

Precision air conditioner
Precision air conditioner
Data center cooling and UPS room
Data center cooling and UPS room
Models & specifications

ADS / AD Series · 3.5–110 kW

Selected models and nominal values. The quotation confirms the exact configuration, battery, and documentation for the project.

Request a model sheet

Precision AC capacity range

SeriesCapacityFormatTypical roomNotes
ADS-025–04225–42 kWRoom-levelSmall data centerAir-cooled
ADS-052–07252–72 kWRoom-levelMedium data centerAir / chilled water
ADS-082–10282–102 kWRoom-levelLarge data centerAir / chilled water
AD-3.5–12.53.5–12.5 kWRow / wallEdge roomCompact

Cooling

Room-level capacity
25 / 30 / 35 / 42 / 52 / 62 / 72 / 82 / 92 / 102 kW
Row / small room
3.5 / 5 / 7.5 / 12.5 kW
Cooling type
Air-cooled or chilled water
Refrigerant
R410A
Airflow
EC fans, model-dependent
Humidity
Controlled with humidifier/dehumidifier options

Installation and control

Format
Room-level, row-level, wall-mount
Monitoring
RS485, dry contacts
Redundancy
N+1 by unit
Power supply
380/400/415 VAC, 3-phase
Outdoor unit
Remote condenser, model-dependent

Key specifications

ParameterValue
Room-level25–110 kW
Row / small room3.5–12.5 kW
CoolingAir-cooled or chilled water
ControlTemperature and humidity
RefrigerantR410A
MonitoringRS485 / dry contacts

Selection notes for this family

QuestionWhat to checkWhy
Load profileRunning kW and largest step for 3.5–110 kWAvoid overload and oversizing
RuntimeBattery bank and charger for the target minutesActual autonomy
EnvironmentTemperature, altitude, dust and ventilationLife and derating
InterfaceMonitoring, bypass, parallel requirementIntegration with the room
DocumentationConformity route and model test reportCustoms and tender
Applications

Where this family fits.

These are the load types the platform is specified for. If your load is outside this list, send the load profile before selecting the model.

  • Data centers
  • Server rooms
  • Telecom rooms
  • Laboratories
  • Equipment rooms
FAQ

Precision AC: project questions.

Project-specific answers. If your question is not here, send the load list and the site conditions.

Talk to an engineer

How much cooling does a data center need?

The cooling load is approximately the IT electrical load plus the UPS and lighting losses. A 100 kW IT load needs about 100–120 kW of cooling, distributed across N+1 units.

Precision AC or comfort AC?

A comfort unit is designed for people and cycles on/off. A precision unit holds temperature and humidity within a tight band and runs continuously. Use precision AC for equipment rooms.

Can it be integrated with the UPS room monitoring?

Yes, RS485 and dry contacts can be connected to the room monitoring system. Confirm the protocol with the BMS/DCIM integrator.

Do you provide the outdoor unit?

The air-cooled configuration includes the outdoor condenser, model-dependent. Confirm the heat rejection path and the available outdoor space.

How is redundancy achieved?

N+1 redundancy is achieved by adding one more unit than the load requires. The units share the load and the controller rotates the duty.

Next step

Send the load list. We will return the configuration.

Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.

  • Capacity and topology recommendation
  • Battery bank and runtime estimate
  • Model sheet and commercial offer

Request a configuration and quotation