UPS YT-R / UM / RT · 1–60 kVA

Rack-Mount UPS

Double conversion in 1U–3U, built for racks and edge rooms.

  • 1–60 kVA
  • 1U–6U
  • 0 ms transfer

Rated capacity

1–60 kVA

Chassis height

1U–6U, by model

DC bus

24–192 VDC

Rack-mount online UPS in a tower orientation

Rated range

1–60 kVA

Rated capacity
1–60 kVA
Chassis height
1U–6U, by model
DC bus
24–192 VDC
Transfer time
0 ms
Output PF
0.8–0.9
Monitoring
RS-232 / USB; SNMP optional
TL;DR

A rack-mount online UPS from 1 kVA to 60 kVA in 1U–6U formats, with external battery packs and SNMP monitoring. Choose it when the load already lives in a rack and the UPS should not take floor space or a separate room.

Overview

What this platform is built to do.

Rack-mount UPS systems put a true online topology into standard 19-inch racks. The YT-R and UM families cover 1–10 kVA with 1U, 2U, and 3U chassis, front-panel LCD, and 0 ms transfer. They are used in server rooms, edge cabinets, network points of presence, and security racks where floor space is not available.

The input stage accepts 85–300 VAC on high-voltage models and the output is a pure sine wave with THD below 3% on linear loads. Standard models include internal batteries for short runtime; long-runtime models use external battery packs in the same rack. Communication includes RS-232 or USB, with SNMP and dry-contact options for building management and remote monitoring.

For a rack deployment, confirm the usable depth, the rail kit, the battery pack height, and the airflow direction. A 1U unit with an external battery pack can need 3U–4U in total; a 3U long-runtime model may need 6U–8U with batteries. The rack thermal load is the sum of the UPS losses and the battery recharge, not just the IT load.

Rack-native

Standard 19-inch mounting with rail kits and front-to-back airflow.

Online topology

Double conversion and 0 ms transfer, not a line-interactive compromise.

External runtime

Add battery packs in the same rack for 30–120 minutes.

Remote alerts

SNMP and dry contacts for NOC, BMS, and alarm panels.

Rack-mount UPS, tower orientation
Rack-mount UPS, tower orientation
1U rack UPS with LCD display
1U rack UPS with LCD display
Rack UPS installed in a server room
Rack UPS installed in a server room
Models & specifications

YT-R / UM / RT · 1–60 kVA

Selected models and nominal values. The quotation confirms the exact configuration, battery, and documentation for the project.

Request a model sheet

Rack-mount online UPS models

ModelCapacityReal powerDC busFormatBattery
YT1KR1 kVA800 W24 V1U / 2UInternal
YT2KR2 kVA1,600 W48 V2UInternal
YT3KR3 kVA2,400 W72 V2U / 3UInternal
YT6KRS6 kVA5,400 W192/240 V3UExternal
YT10KRS10 kVA9,000 W192/240 V3UExternal
UM-1KR1 kVA800 W24 V1UInternal
UM-2KR2 kVA1,600 W48 V2UInternal
UM-3KR3 kVA2,400 W72 V2U / 3UInternal
RT33-10K–60K10–60 kVA9–54 kW384 VDCRackExternal
RT11-1K–10K1–10 kVA0.8–9 kW24–192 VDCRackInternal / external

Electrical

Input
Single-phase 208/220/230/240 VAC, 85–300 VAC range
Output
220/230/240 VAC ±2%, pure sine wave
THD
< 3% linear / < 7% non-linear (1–3 kVA); < 2% / < 6% (6–10 kVA)
Transfer
0 ms mains ↔ battery
Overload
105–125% for 1–10 min; 126–150% for 30–60 s

Mechanical

Mounting
19-inch rack, 1U–3U by model
Depth
Model-dependent; confirm rack depth and rear clearance
Airflow
Front-to-back forced ventilation
Rail kit
Included or optional by model

Battery and monitoring

Battery
Internal for standard models; external pack for long runtime
DC bus
24 / 36 / 48 / 72 / 96 / 192 VDC by model
Interface
RS-232 or USB; SNMP card optional
Software
Windows, Linux, macOS shutdown

Key specifications

ParameterValue
Rated capacity1–60 kVA
Chassis height1U–6U, by model
DC bus24–192 VDC
Transfer time0 ms
Output PF0.8–0.9
MonitoringRS-232 / USB; SNMP optional

Selection notes for this family

QuestionWhat to checkWhy
Load profileRunning kW and largest step for 1–60 kVAAvoid overload and oversizing
RuntimeBattery bank and charger for the target minutesActual autonomy
EnvironmentTemperature, altitude, dust and ventilationLife and derating
InterfaceMonitoring, bypass, parallel requirementIntegration with the room
DocumentationConformity route and model test reportCustoms and tender
Applications

Where this family fits.

These are the load types the platform is specified for. If your load is outside this list, send the load profile before selecting the model.

  • Server rooms
  • Edge cabinets
  • Network PoP sites
  • Security control rooms
  • Branch IT closets
FAQ

Rack UPS: project questions.

Project-specific answers. If your question is not here, send the load list and the site conditions.

Talk to an engineer

How much rack space does a 3 kVA rack UPS need?

A 3 kVA online rack UPS is typically 2U–3U, plus battery space. Long-runtime configurations can need 4U–6U in total. Confirm the chassis depth and the rail kit before ordering.

Can I add external batteries to a standard rack UPS?

Only if the model is designed for an external pack. Standard models with internal batteries have a fixed DC bus and charger; connecting a larger bank without checking the charger can damage the battery.

Is the rack UPS loud?

Online rack UPS units use forced ventilation. Noise is typically below 55 dB at 1 m, but small racks in occupied rooms should account for fan noise and heat.

Does it support remote shutdown?

Yes. RS-232 or USB with vendor software supports graceful shutdown; SNMP provides network alerts and can trigger shutdown scripts.

Can I install it in a sealed cabinet?

Only with adequate ventilation. The UPS and battery pack reject heat into the rack; a sealed cabinet will overheat. Plan the thermal load and airflow path.

Next step

Send the load list. We will return the configuration.

Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.

  • Capacity and topology recommendation
  • Battery bank and runtime estimate
  • Model sheet and commercial offer

Request a configuration and quotation

Send the load list, backup time, and site conditions. We will return a capacity recommendation, battery configuration, and commercial offer.

By submitting this form you agree to our privacy policy. Privacy policy

Published Last updated Specifications and certification are confirmed per project.