The documents and tools behind the quote.
A project needs more than a price: the model sheet, the drawing, the battery configuration, the monitoring map, and the test record. Start here.
- Datasheets
- On request
- Monitoring
- SNMP / MODBUS
- Test basis
- IEC 62040
- Model coverage
- 400 VA–800 kVA
Datasheets & drawings
Model sheets, dimension drawings, single-line diagrams, and commissioning checklists on request.
OpenRemote monitoring
SNMP, MODBUS, dry contacts, and battery monitoring for unmanned sites and DCIM integration.
OpenCertifications
CE, ISO 9001, RoHS, IEC 62040, and UN38.3 documentation by model and market.
OpenSizing calculator
Convert kW to kVA, choose a standard size, and estimate the 12 V battery blocks.
OpenSupplier & quotation
MOQ, OEM/ODM, documentation, Incoterms, and the quotation checklist.
OpenFactory & quality
Incoming inspection, burn-in, load test, final inspection, and export packing.
OpenSupport here means five artefacts — the model datasheet, the dimension drawing, the single-line diagram, the battery configuration sheet and the test record — plus a monitoring map where the site is unmanned. Each one is issued against a specific model, frame and revision, so the request needs to name them.
Which document answers which question?
The fastest way to get the right file is to ask for the question you are trying to settle, not the document name. The table maps one to the other.
| What you need to settle | Ask for | Issued against |
|---|---|---|
| Is this the right capacity? | Sizing worksheet | Load list, runtime target, power factor |
| Will it fit in the room? | Dimension drawing and weight | Frame plus battery cabinet |
| How is it wired to the board? | Single-line diagram | Frame, bypass and changeover arrangement |
| How long will it run on battery? | Battery configuration sheet | String voltage, Ah, load curve |
| Will it pass the tender? | Test report and certificate scope | Model number, standard, revision date |
| Can I see it remotely? | Monitoring map | SNMP / MODBUS card and point list |
| What proves it was tested? | Factory test record | Serial number, load test, burn-in duration |
Send the model or the project reference with the request. A document that is not issued for your frame is worse than no document: it invites a tender submission on the wrong basis.
Documents and quality records.
Documentation package
| Document | Contents | Typical use |
|---|---|---|
| Model datasheet | Ratings, input/output, battery, dimensions | Design and tender |
| Dimension drawing | Cabinet size, terminals, clearance | Room layout |
| Single-line diagram | UPS, bypass, battery and breakers | Electrical design |
| Battery configuration | String voltage, blocks, runtime basis | Battery procurement |
| Test report | Model-specific IEC 62040 or CE report | Compliance and customs |
| Packing list | Dimensions, weight, HS code, marks | Shipping and clearing |
Quality process and records
| Step | Check | Record |
|---|---|---|
| Incoming | Transformer, PCB, fan, breaker, battery | Incoming sheet |
| Assembly | Wiring, busbar, control board, labels | Work checklist |
| Burn-in | Powered run at load | Burn-in log |
| Load test | Rated load, overload, transfer, battery | Load test report |
| Final | Torque, paint, accessories, documents | Final inspection |
| Packing | Foam, case, desiccant, marks | Packing list and photos |
Send the load list. We will return the configuration.
Tell us the kW, the backup time, the phase, and the site country. You will get a capacity recommendation, a battery configuration, and the model sheet.
- Capacity and topology recommendation
- Battery bank and runtime estimate
- Model sheet and commercial offer
Request a configuration and quotation
Send the load list, backup time, and site conditions. We will return a capacity recommendation, battery configuration, and commercial offer.